Devicenet Configurator Software

  

Sep 01, 2016 Basic Functions. Virtual network management, device settings (I/O allocations, connection settings), device monitoring, device (EDS file) management, and online connections to DeviceNet devices. Configurator network configuration files (.npf) Configurator device parameter files (.pvf) Files created. Addresses not be used. The configuration of this device can be performed using Cutler-Hammer’s NetView configuration software, or Rockwell’s RSNetWorx DeviceNet configuration software. Use the WPONIDNA Instruction Leaflet (I.L. 24659) to make a decision as to which Input/Output Assembly will be used. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators.

. Role of RSNetWorx for DeviceNet software These topics are covered briefly in this chapter and in more detail throughout the rest of the manual. Topic Page Module Features 12 Scanner Module Operation 13 Communication with Your Slave Devices 14 1769-SDN Scanner Module Data Tables 15 RSNetWorx for DeviceNet Software as a Configuration Tool 17.

If you had a controller that does DeviceNet messaging, you could just attach the StoneL devices to the controller's network and send configuration messages addressed to the 'DeviceNet Object', which contains the baud rate, autobaud option, and node number settings. The cost would be only your time in learning how to program DNet messages on your controller.
I work almost exclusively with Allen-Bradley devices, and A-B has three PC-to-DeviceNet products: 1784-PCD (PCMCIA), 1770-KFD (RS232 serial) and 1784-U2DN (USB). RSLinx Lite communications software and the DeviceNet Node Commissioning Tool are both free of charge.
The A-B devices are fairly expensive, though for a quick and simple task like this I'll bet you could borrow one from your local Rockwell Automation office, especially if you gave them an opportunity to discuss their I/O products.
Most vendors have their own node commissioning tools that are specific to their interface device. Rockwell, Woodhead/Molex, Softing, IXXAT, Hilscher.... all of them sell DeviceNet interfaces that have utility tools.

A-DNTR

The DeviceNet Router provides a powerful and easy to configure solution to exchange data between DeviceNet™ devices and a Logix controller or PanelView via EtherNet/IP™. The module is able to asynchronously exchange data between a DeviceNet polling master (scanner) and an Ethernet PCCC device. Produced and consumed data sizes are independently configurable from 0 to 128 bytes each.

The consumed (DeviceNet) data can then be mapped to a PLC5 type address file, e.g. N33, and then read by an Ethernet device e.g. a PanelView. Similarly, the produced data (DeviceNet) can also be mapped to a PLC5 type address file, to which an Ethernet device could write. The Router supports transferring parameters from a DeviceNet device directly to Logix tags. The scaling of the parameter values will either be extracted from the EDS file imported or can be manually updated by the user. The module also provides a range of statistics and an on-board DeviceNet traffic analyzer to assist with fault finding. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of DeviceNet operation and communication statistics, without the need for any additional software.

Devicenet Configurator Software Free

Architectures

Features and Benefits

Devicenet Configurator Software Download

  • DeviceNet to Ethernet Interface
  • PCCC or EtherNet/IP protocols
  • PLC5 Emulation Mode
  • Direct-to-Tag Technology
  • Advanced Diagnostics, including packet capture

Configuration

The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the DeviceNet Router module, connections with controllers and devices.

Specifications

Devicenet Configurator Software Windows 10

Software

Devicenet Configurator Software Windows 10

EtherNet/IP Network

Specification

Description

Connector

RJ45

Conductors

CAT5 STP/UTP

ARP Connections

Max 20

TCP Connections

Max 20

CIP Connections

Max 10

Communication Rate

10/100 Mbps

Duplex Mode

Full / Half

Auto-MDIX Support

Yes

DeviceNet Network

Specification

Rating

Connector

5-way terminal, 5.08 mm pitch.

Conductors

12 to 30 AWG

Baud Rate

125k, 250k, 500k

IO Messaging

Polled

Change of State (COS)

Unconnected Message Manager (UCMM)

Yes

Max Explicit Connections

5

PCCC Network

Specification

Description

Max PCCC Connections

10

Max PCCC Payload

1000 bytes

Hardware

Specification

Rating

Power Supply

Input: 10 to 28 VDC, (70 mA @ 24VDC)

Power Consumption

1.7 W

Dimensions (H x W x D)

101.0 x 22.5 x 120.0 mm

Connector

5-way terminal, 5.08 mm pitch.

Conductors

24 to 18 AWG

Enclosure Rating

IP20, NEMA/UL Open Type

Temperature

-20 to 70 °C

Humidity

0 to 95% RH, non-condensing

Earth Connection

Yes, terminal based

Emissions

IEC61000-6-4

ESD Immunity

EN 61000-4-2

Radiated RF Immunity

IEC 61000-4-3

EFT/B Immunity

IEC 61000-4-4

Surge Immunity

IEC 61000-4-5

Conducted RF Immunity

IEC 61000-4-6

Downloads

DeviceNet Router Datasheet675.12 kBLast Modified 09/04/2020
DeviceNet Router Quick Start Guide414.62 kBLast Modified 06/30/2020
DeviceNet Router User Manual4.38 MBLast Modified 06/30/2020
DeviceNet Router EDS Files1.77 kBLast Modified 06/30/2020
DeviceNet Router Examples224.01 kBLast Modified 07/02/2020
Slate Software v1.05340.18 MBLast Modified 11/18/2020

Certifications

Certificate of RoHS Compliance 222.76 kBLast Modified 09/28/2020
UL/cUL; Class1, Div 2 351.49 kBLast Modified 10/01/2020